• Running light transformer
  • Running light transformer
  • Running light transformer
  • Running light transformer
  • Running light transformer
  • Running light transformer

Running light transformer

JMB, DG, BJZ, BZ series lighting transformers are suitable for circuits with AC 50HZ and voltage 500V or below, as local lighting power supply for machine tools and other equipment.
  • Running light transformer
  • Running light transformer
  • Running light transformer
Description
Product Features

JMB, DG, BJZ series transformers are composed of BK series transformers and protective casings. There are terminals on both sides of the casing for input power and load wiring, and grounding screws for grounding; BZ type lighting transformers are composed of BK-50, BK-100 control transformers, LS3-2 type main switch and protective casings. A fuse is installed on the main switch to protect the lighting circuit. The power supply is introduced from the dustproof film at one end of the main switch, and the lighting lamp is connected and disconnected through the main switch.

Model and meaning
Driving light transformer model and meaning       Driving light transformer model and meaning       Driving light transformer model and meaning         Driving light transformer model and meaning           Driving light transformer model and meaning

Shape and installation dimensions

 Driving light transformer appearance and installation dimensions                                Driving light transformer appearance and installation dimensions                                Driving light transformer appearance and installation dimensions                                 Driving light transformer appearance and installation dimensions

model

Rated capacity(VA)

Secondary voltage(V)

Primary voltage(A)

Overall dimensions (mm)

Mounting holes

B

D

E

BZ-50H

50

380 / 220V

12/24/36

118*212*92

Φ6.5

BZ-100H

10

118*212*104

Φ6.5

 

JMB (BJZ/DG) models and installation dimensions

Primary voltage

Secondary voltage

Model Specifications

Dimensions

B

D

E

 

 

 

220V/380
or customized according to customer needs

 

 

 

 

 

63/12/24/36/110/
127/220/380

Special voltage can be customized

 

JMB(BJZ/DG)25VA

145

160

120

JMB(BJZ/DG)50VA

145

165

120

JMB(BJZ/DG)100VA

145

165

120

JMB(BJZ/DG)150VA

165

155

130

JMB(BJZ/DG)200VA

165

155

130

JMB(BJZ/DG)250VA

175

200

150

JMB(BJZ/DG)300VA

175

200

150

JMB(BJZ/DG400VA

205

230

170

JMB(BJZ/DG)500VA

205

230

170

JMB(BJZ/DG)700VA

220

285

180

JMB(BJZ/DG)1000VA

200

285

180

JMB(BJZ/DG)1500VA

260

320

220

JMB(BJZ/DG)2000VA

260

320

220

JMB(BJZ/DG)3000VA

260

360

240

JMB(BJZ/DG)5000VA

365

350

240


 Precautions for use

1. The ambient air temperature is -25℃ to +40℃, and the average value for 24 hours does not exceed +35℃;
2. The altitude of the installation site does not exceed 2000m;
3. The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃. A higher relative temperature can be achieved at a lower temperature. The average maximum humidity in the wettest month is 90%, and the average minimum temperature of the month is +25℃, taking into account the condensation on the surface of the product due to temperature changes.
4. A place without severe vibration and impact vibration.
5. A place not affected by rain or snow.
6. The voltage waveform is approximately a sine wave.

 

■Remarks

When ordering, please specify: model, capacity, input voltage, output voltage;


Friendly reminder: special voltage can be customized